<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Scientific-Research Quarterly Journal of Technical Science</title>
<title_fa>فصلنامه علمی - تحقیقی علوم فنی</title_fa>
<short_title>JOTS</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://jots.knu.edu.af</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn></journal_id_issn>
<journal_id_issn_online></journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>doi</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1402</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2024</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<volume>1</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>معرفی و بررسی اضافه‌ولتاژهای بازگشتی و شبیه‌سازی موردی آن در نرم‌افزار EMTP_RV</title_fa>
	<title>Introduction and review of Transient Recovery Voltages and its case simulation in EMTP_RV software</title>
	<subject_fa>عمومى</subject_fa>
	<subject>General</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;ولتاژ بازیابی گذرا (TRV) یکی از مشخصه&#8204;های ذاتی در سیستم قدرت است که حداکثر و سرعت افزایش آن از عوامل مهمی هستند که بر روند کلیدزنی در سیستم قدرت تاثیر می&#8204;گذارند. هنگامی که یک سیستم قدرت دارای ویژگی&#8204;هایی از TRV باشد به این معنا است که ولتاژ از محدوده تحمل کلیدها بیشتر بوده و ممکن است کلیدهای مدار، جریان خطا را قطع نکنند. در این مقاله، ابتدا انواع اضافه&#8204;ولتاژها در سیستم قدرت بررسی شده است. در ادامه، اضافه&#8204;ولتاژهای ناشی از کلیدزنی (پدیده&#8204;ای مهم در شبکه قدرت) معرفی شده است. اهمیت بررسی این موضوع، تاثیر این اضافه&#8204;ولتاژها هنگام عملکرد کلیدهای قدرت می&#8204;باشد که به دلیل پیچیده بودن شبکه&#8204;های قدرت از وجود ساختارهای متفاوت، وقوع خطاهای مختلف با شکل موج&#8204;ها و ساختارهای متفاوت تاثیر می&#8204;پذیرند. وجود این شکل موج&#8204;های مختلف بر عملکرد کلیدهای قدرت تاثیر مستقیم خواهد داشت که ممکن است کلیدها قابلیت تحمل این تنش&#8204;ها را نداشته و قطع مدار ناموفق باشد. از سوی دیگر، عملکرد ناموفق کلیدها در شرایط خطا امکان به بارآورن خسارت به شبکه در هنگام شرایط بحرانی را خواهد داشت. در ادامه این پژوهش، برای مشاهده تنش&#8204;های حاصل از کلیدزنی به شبیه&#8204;سازی موردی در نرم&#8204;افزار حالت گذرایی EMTP_RV پرداخته شده است.&lt;/div&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;Transient recovery voltage (TRV) is one of the characteristics inherent in the power system, and its maximum and increasing speed are important factors that affect the switching process in the power system. When a power system has characteristics of TRV, it means that the voltage is higher than the tolerance range of the switches and the circuit breakers may not interrupt the fault current. In this article, the types of overvoltages in the power system have been investigated first. In the following, overvoltages caused by switching (an important phenomenon in the power network) are introduced. The importance of investigating this issue is the effect of these overvoltages during the operation of power switches, which are affected by the existence of different structures, the occurrence of different errors with different waveforms and structures due to the complexity of power networks. The presence of these different waveforms will have a direct effect on the performance of the power switches, which may not be able to withstand these stresses and the circuit may fail. On the other hand, the failed operation of the keys in error conditions will have the possibility of causing damage to the network during critical conditions. In the continuation of this research, in order to observe the stresses resulting from keying, case simulation has been done in EMTP_RV transient mode software.&lt;/div&gt;</abstract>
	<keyword_fa>اضافه‌ولتاژ برگشتی, کلید, پیک ولتاژ, RRRV</keyword_fa>
	<keyword>recovery overvoltage, switch, peak voltage, RRRV</keyword>
	<start_page>61</start_page>
	<end_page>85</end_page>
	<web_url>http://jots.knu.edu.af/browse.php?a_code=A-10-1-4&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Abdullah</first_name>
	<middle_name></middle_name>
	<last_name>Halimi</last_name>
	<suffix></suffix>
	<first_name_fa>عبدالله</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حلیمی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Master&#039;s student of power systems at K. N. Toosi University of Technology, Tehran, Iran</affiliation>
	<affiliation_fa>دانشجوی کارشناسی ارشد سیستم‌های قدرت، دانشگاه صنعتی خواجه نصیرالدین طوسی، تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
